3 wavelength laser hair removal equipment

Shop the 2in1 Soprano Titanium Ice Platinum Diode Laser. This ND:YAG device options three wavelengths (755, 808, 1064nm) for pain-free hair elimination.
2-in-one Soprano Titanium Ice 4000W Triple Wavelength Diode & ND:YAG Laser Device
Obtain Specialist-grade outcomes Using the Soprano Titanium Ice Platinum, a robust two-in-one technique combining three-wavelength diode laser technological innovation for painless hair removing as well as a Q-Switched ND:YAG laser for tattoo elimination and skin rejuvenation. Equipped with a 4000W high-ability motor and five-degree adjustable cooling engineering, this CE-certified equipment supplies Secure, economical, and long lasting results for all pores and skin types and overall body locations.

Hair Removing: Triple wavelength (755nm, 808nm, 1064nm) for all skin tones
Pores and skin Correction: Q-Switched ND:YAG for tattoo removing and carbon peeling
Convenience: five-Degree adjustable cooling procedure for any pain-free practical experience
Electrical power: 4000W high-Electricity density with German Diode Arrays

Crucial Options
3-Wavelength Diode Engineering: Integrates 755nm (Alexandrite), 808nm (Pace), and 1064nm (YAG) wavelengths into only one applicator to focus on unique hair depths and constructions concurrently.
Twin-Functionality Process: A real 2-in-one workstation that includes a committed Diode laser for long lasting hair reduction as well as a Q-Switched ND:YAG laser for pigmented lesion procedure and tattoo removing.
Superior five-Level Cooling: Characteristics the “Titanium Ice” 5-level adjustable cooling technology that retains the sapphire tip at an optimal temperature, ensuring the cure remains relaxed and painless.
Significant Output Efficiency: Pushed by a massive 4000W electric power provide and German-imported Diode arrays, offering around 2000mj Strength density for quick and helpful clinical effects.
Huge Touchscreen Interface: Geared up having a substantial-definition interactive display for precise Manage about Power amounts, pulse frequency, and cooling depth across various treatment method modes.
Compatibility & Best Use
Entire System Software: Protected and productive for use within the experience (higher lip, chin), underarms, bikini line, arms, legs, back, and chest.
All Skin Forms: The triple wavelength system is made to operate correctly on all skin tones (Fitzpatrick scales I-VI) and hair colours, which includes high-quality and lightweight hair.
Skin Rejuvenation: Use the ND:YAG handle Using the black doll (carbon) tip for deep pore cleansing, skin whitening, and anti-getting older solutions.
Tattoo & Pigment Removal: Goal darkish and coloured inks precisely using the Q-Change frequency for non-invasive elimination website of tattoos and freckles.
Set up Strategies
Water Cooling Setup: This substantial-ability laser demands distilled drinking water for its cooling program; ensure the drinking water tank is stuffed to your proposed level just before powering about the equipment for The 1st time.
Cope with Relationship: Carefully align the pins from the laser handles Together with the device ports and safe the locking mechanism to be sure steady sign and cooling fluid transmission.
Voltage Verification: The device supports 110V and 220V; make certain your electricity outlet matches the particular voltage options from the machine to stop electrical injury.
Parameter Calibration: For new customers, it is recommended to get started on treatment plans at the bottom Strength settings and gradually maximize based upon the customer’s skin sensitivity and feedback.
Products Requirements
Brand more info name Identify emszero
Product Range Titanium 2-in-1 (4000W)
Laser Wavelengths 755nm, 808nm, 1064nm (Diode) / 532nm, 1064nm, 1320nm (ND:YAG)
Ability Output 4000W
Strength Density Around 2000mj (Adjustable)
Cooling Level five Stages Adjustable Sapphire Cooling
Certification CE
Voltage Compatibility AC 110V/220V, 50/60Hz
Packing List
one x Soprano website Titanium 2-in-1 Most important Console (4000W)
one x 3-Wavelength Diode Laser Handle
one x Q-Change ND:YAG Laser Manage
3 x Specialised ND:YAG Guidelines (532nm, 1064nm, 1320nm)
1 x Power website Cable & Foot Pedal
one x User Handbook & Protecting Goggles Set

Warnings & Security Notes
Eye Protection: Constantly dress in the provided laser-protection goggles through operation to prevent lasting eye injury from stray laser reflections.
By no means Operate Dry: check here Tend not to operate the equipment with no filling it with distilled water; functioning the laser with out a functioning cooling loop will end in quick internal components failure.
Contraindications: Don't use this machine on regions with open wounds, Energetic bacterial infections, or on individuals who are Expecting or have gentle-sensitive health care circumstances.
Cooling Routine maintenance: Change the distilled h2o each three months to ensure The interior pump and laser arrays remain freed from mineral buildup and overheating.

Leave a Reply

Your email address will not be published. Required fields are marked *